Skip to content
ICC-CI — International Concrete Company
Concrete and structure, material awaiting installation.

Quality

Quality at the core of production.

The requirements published here concern electrical poles first, for which the documentation sets a dosage, a cycle and a target strength.

A manufacturing reference, named precisely.

Electrical poles are manufactured in accordance with French standard NF C 67-200 of December 1981. This is the product reference cited by the company. It should not be read as an organisation certification, nor as an ISO accreditation. No such certification is claimed.

35

Target strength of poles at maturity

28

Pole maturity before delivery

NF C 67-200

Manufacturing reference for poles

What is controlled

01

Dosage

Approximately 400 kg of cement per cubic metre for poles.

02

Cycle

Vibration, approximately 24 hours before demoulding, approximately 28 days of curing.

03

Strength

A target of approximately 35 MPa at pole maturity.

04

Steel

FeE 500 reinforcement, from HA 6 mm to HA 16 mm.

Electrical poles

  • CPA or CHF cement
  • Granite gravel 5/15 and 15/25
  • Washed lagoon sand
  • FeE 500 reinforcing steel: HA 6, 10, 12, 14 and 16 mm

Concrete blocks

  • CPA cement
  • 0.5 gravel
  • Washed lagoon sand

All materials used in manufacturing are available in Côte d’Ivoire.